Iu22 User Manual

2021年6月5日
Download here: http://gg.gg/uv9dn
*Philips Iu22 User Manual Pdf
*Philips Iu22 Ultrasound
*User Manual Template
In the body, different tissues and organs iU22 User Reference 70891 Safety 2 have dissimilar attenuation characteristics. In water, there is almost no attenua- tion. In the body, and in particular, in water tank measurements, non-linear propa- gation and saturation losses occur as pulser voltages increase. The iU22 ultrasound system gives you exceptional image quality, ease of use, automatic quantification, and throughput to help you address the challenges you face in your vascular lab. In the body, different tissues and organs iU22 User Reference 70891 Safety 2 have dissimilar attenuation characteristics. In water, there is almost no attenua- tion. In the body, and in particular, in water tank measurements, non-linear propa- gation and saturation losses occur as pulser voltages increase.
The iU22 and iE33 ultrasound systems are general-purpose, mobile, software-controlled, diagnostic ultrasound systems for general imaging and cardiology and vascular applications. For the applications available with each system, see “iU22 Applications” on page 73 and “iE33 Applications” on page 74.
In the Philips IU22 ultrasound system, Philips uses volume imaging and the ViewForum workstation to view ultrasound in the same format as CT and MR. And by using the Philips IU22 transducer guide, you can better understand your system and the probes it needs for the services you want to provide.
Exam times are reduced by as much as 38 percent while using the Philips IU22 ultrasound. The Philips IU22 model offers tissue aberration correction on breast transducers, body contrast-enhanced ultrasound for more definitive diagnosis, and exam time reduction with SmartExam.
Use the Philips IU22 ultrasound transducer guide below for reference and when you find the ultrasound probe you need, contact us by filling out a form or call 317.204.3012.
At Probo Medical, we buy, sell, and repair ultrasound probes and stock systems from industry-leading OEM’s. Our mission is to deliver the perfect probes and systems at a wholesale cost to every customer, every time.
Looking for a transducer guide for a different system? View our full list of guides! You can also visit our partner company Ultrasound Supply to shop for Philips IU22 ultrasound machines.Philips iU22 Transducer GuideProbe NameBandwidthFOV4D ConvexV6-22-6 MHz100°4D LinearVL13-55-13 MHz4D Endovaginal3D9-3v3-9 MHz164°LinearL9-33-9 MHzL12-5 50 mm5-12 MHzL17-55-17 MHzIntraoperative LinearL15-7io7-15 MHzConvexC5-11-5 MHz96°C5-22-5 MHz115°C9-44-9 MHz108°MicroconvexC8-55-8 MHz120°EndovaginalC8-4v4-8 MHz160°C10-3v3-10 MHz164°EndocavitaryC9-5ec5-9173°Cardiac SectorS3-11-3 MHz90°S4-11-4 MHz90°S5-11-5 MHz90°TEES7-2omni2-7 MHz90°S7-22-7 MHz90°xMatrixX3-11-3 MHz90°X5-11-5 MHz100°X6-11-6 MHz100°X7-22-7 MHz90°xMatrix TEEX7-2t2-7 MHz90°PedoffD2TCC2 MHzD2CWC2 MHzD5CWC5 MHzPhilips Iu22 User Manual PdfAbout Probo Medical
Probo Medical is a comprehensive medical device company that provides a wide range of diagnostic ultrasound services through intelligent affordability.
Our offerings include:
*Ultrasound Sales
*Ultrasound Service and Loaners
*Ultrasound Rentals
*Ultrasound Probe Repair (including TEE)
*C-arm Sales, Service and RentalsDiscover the Power of Intelligent Affordability
Intelligent Affordability means customers can own refurbished medical equipment that looks and runs like brand new for a fraction of the manufacturer’s price. Our extensive supply chain for new and used equipment along with our refurbishment and technical expertise allows customers to make smarter decisions with their capital and operating budgets without sacrificing patient care. Probo Medical offers the best of both worlds: quality medical equipment at low prices.Maintaining and Troubleshooting the Philips iU22/iE33 Ultrasound Systems
The Philips iU22 and iE33 ultrasound systems are excellent general imaging, vascular and
File name: ST-4905.rar Upload Date: 2017-09-02T17:31:45.000Z Size: 566912. ContentcopyThis file is hosted at free file sharing service 4shared. DONLOAD LINK Download Free Canon Service Tool v.4905 LINK: How To use the Service Tool v.4905 LINK: http://bit.ly/TutorCanonST490. Canon service tool download. Jan 03, 2019 Canon Service Tool This Service tool v4905 support for G1000, IP2770, IX6560, MP258, MG6170 printer also for G Series, IX Series, IP Series, MG Series, MP Series, MX Series, and PRO Series. Click links below to download for free. Download Service Tool v4905 (password: errorandreset.com) or link 2. Canon Service Tool V4905 (Multi-PC) G Series: G1000, G2000, G3000.
cardiology units that have gained a very large share of the market over the last 10 years. There
are several maintenance tips and common problems that service providers should be aware of
on these systems.
Let’s begin with how to prevent malfunctions and extended downtime. These systems can
be prone to overheating due to the air intakes being so close to the ground. Depending on the
environment (dusty, linen usage, etc.) the filters on the rear access panel and lower left side
panel should be cleaned quarterly or even more often to ensure adequate airflow to the power
supplies, acquisition and platform sections of the systems. There are also cooling vents inside
the rear wheel wells that should be vacuumed at the same intervals.
Also ensure current backups of the system’s presets and option files are made. The
presets are backed up via the system setup menu but the option files are made through Tech
Admin. Having a proper backup is critical to mitigating downtime in the event of software
corruption or a hard drive failure.
One of the most common problems with these systems is related to video. The main
display communicates with the main computer (Host, UMB or EMB) and can show a partial
display during the boot cycle but go blank upon system initialization. This is indicative of a bad
main display despite it functioning during the boot cycle. Next, are the dual video cards
contained in the Platform (Back End). On A-C cart systems, the Host and SIP computers eachPhilips Iu22 Ultrasound
contain a video card and on D-G cart systems, the UMB or EMB will have both. If video is
missing from the main display or touch panel(s), you can swap the video cards to see if the
symptoms change. There are several versions which are not interchangeable.
The ECG ports on these systems are part of the FEC board in the Acquisition section of
the system and the port can be damaged by the ECG cable to the patient area being stressed.
A cable tie attaching the main ECG cable to the system handle can prevent this.
One of the most unusual problems we have encountered is the intermittent or fixed issue
of DICOM transmissions failing which we have found is due to a failure in the main power cord
ground.
These are some of the more common problems and we welcome complimentary technicalUser Manual Template
support requests at 866-900-9494.